What is happening with SAP 10.3 and HEM

A new version the of the Part L compliance calculation methodology (known as SAP 10.3) has been published. This will be the approach used for the first wave of Part L 2026 homes delivered from 2027. (For more info – Click here)


As trailed in the FHS Consultation, there will be a new, more detailed assessment methodology, known as the Home Energy Model (HEM) available later in 2026, after a period of dual running (circa 2 years) HEM will become the main compliance methodology for all new homes. (For more info – Click here).


The notional dwelling specifications have moved for Part L 2026 from within the main document to only being available in the SAP 10.3 document. Below are the headline changes and a link to the BRE SAP web page to find out more.


  • Fabric specification: Opaque elemental U-values remain unchanged (e.g., external walls at 0.18 W/m²K, roofs at 0.11 W/m²K).
  • New conventions for window & doors: Part L 2026 now requires a change from using a single standardised window and door U-value for all windows in a home, to ones calculated for each window size, frame style and includes additional elements such as sills. Also the notional dwelling window frame factors and solar transmittance now match the actual dwelling specification rather than using fixed defaults.
  • Design air permeability; tightens from 5.0 to 4.0 m³/(h·m²) at 50 Pa
  • Space heating: Shifts from a mains gas boiler (89.5% SEDBUK efficiency) to an all-electric air source heat pump (ASHP) with a fixed Seasonal Coefficient of Performance (SCOP) of 2.5.
  • Space heating controls: Updated from ErP Class V boiler controls to ErP Class II controls.
  • Hot water including storage and controls: Water heating transitions from a gas boiler to an ASHP (SCOP 2.5). Waste Water Heat Recovery (WWHR) efficiency increases from 36% to 50% . Default cylinder sizing changes from a flat 150L to the 75th percentile of daily hot water demand.
  • Ventilation: Moves from natural ventilation with intermittent extract fans to continuous decentralised mechanical extract ventilation (dMEV) with a Specific Fan Power of 0.15 W/(l/s).
  • Photovoltaics: The PV benchmark calculation divisor tightens from 6.5 to 4.5 (40% GFA / 4.5 for houses), requiring a larger array. Notional panel parameters (orientation, pitch, overshading) now mirror the actual dwelling.
  • Heat Networks: Introduces sleeved district heat networks (which copy actual heating specifications). Unsleeved district networks default to the standard ASHP notional specification, while communal networks use a communal heat pump (300% efficiency, 1.15 distribution loss factor).

Relevant resources