Changes to window & door U-value conventions can have wider compliance implications
Under Part L 2026, U-values for windows and doors in new dwellings can no longer be assessed using standard reference sizes or generic configurations (such as a standard 1230mm x 1480mm window). Instead, U-values must be calculated using the actual size and specific configuration of each individual unit.
Calculations must explicitly include all physical profile details, including actual frame sections, sills, thresholds, frame extenders/add-ons, dummy sashes, transoms, mullions, decorative glazing bars, and non-dead-load-bearing couplers. Only dead-load-bearing structural components (such as bay poles) are excluded. This methodology represents a major shift that requires homebuilders and energy assessors to obtain bespoke, opening-specific U-value calculations for every home type.
How might this impact the design specifications for the Fabric Energy Efficiency Standard?
Because bespoke calculations must account for actual frame proportions, frame extenders, and thermal penalties for glazing bars, declared U-values may be higher (worse) than the standardized figures used for Part L 2021.
For some home types this could mean meeting the required FEES, alongside the Notional Dwelling window featuring a U-value of 1.2 W/m²K, will become harder with double glazing, especially for smaller windows with higher frame factors.
To prevent late design changes or FEES failures, technical designers will need to ensure their window supplier provides these new individual window and door U-values as early as possible. Especially if the new Part L 2026 fabric specification is being developed from a previous Part L 2021 design that only passed FEES by a small margin.
For further information on these changes, see the BSI's Future Homes Standard and Approved Document L 2026 Explained article and guidance from the Glass and Glazing Federation (GGF).
Relevant resources